中文版    Dutch     Finnish    Italian    Polish    Portuguese    Saudi     Danish     Czech    Spainish    Russian
| Sign up | Sign in | Add Favorite
 
 
Home News Products Soultions Certification Workshop Quality System Technical Support Download Feedback Contact Us
Products
GSM Home Alarm Systems
Promotion GSM Alarm-Dialer
Economic GSM Alarm System
User Friendly GSM Alarm System
Advanced GSM Alarm Systems
Community Emergency Alarm Solution
GSM Elderly Guarder(Panic Alarm)
GSM SMS Controller Alarms
GSM SMS Controller Alarms
GSM SMS AC Power Alarm
GSM SMS Temperature Alarm
GSM Air-Conditioner IR Controller
Http://www.GSM-M2M.com
GSM Gate Garage Door Openers
GSM Alarm Monitoring Center
GSM SMS Alarm Receiver
GSM Remote Monitoring Center
Alarm Accessories
Remote Controls
Emergency Buttons
Door Contacts
PIR Detectors
Smoke Detectors
Gas Leakage Detectors
Water Leakage Detectors
Photoelectric Beams
Sirens
Others
Wireless Remote Switches
GSM Products Development Service
Contact Us
King Pigeon Hi-tech. Co., Ltd
Add:5/F,Building F,Yusheng Industrial Park,Jiuwei,Xixiang,Bao'an District,Shenzhen,518126,China.
 
Products  
Click it to see the large photo
Name:GSM Alarm System
Model:S100
 
Datasheet

 

 A Top Safety and Protection Solution In The Worldwide!

Name: GSM Alarm System

Model: S100

The GSM Alarm System S100 with multi-functions. It integrated GSM Module inside, and almost all useful functions and features of the alarm systems in the worldwide markets. Also it with innovative and experienced functions and features to meet the required and potential demands.

The GSM Alarm System S100 is a new security protection solution. It is special for home, house and office and other applications. It based on Wireless GSM Communication network; it can alert you by SMS and calling.

The GSM Alarm System S100 supports two way voice communication and wiretap by intelligent technology. It can answer the incoming call as well as dial out to the others. It is very useful for user to create voice communication or listen in the houses.

The GSM Alarm System S100 supports Watchdog, once the sensor in this zone triggered in the preset time, will not alarm, if the sensor hasn’t been triggered in the preset time, will alarm. It is useful for monitoring elders, children and the person on-duty.

The GSM Alarm System S100 equips with two output relay, one is link-output relay, special for switch on or off appliance while the system alarm, another is independent output relay, it can be switched on or off by SMS commands.

The GSM Alarm System S100 equips with LCD display entire operation menu, all operations and settings are visual and intuitive!

The GSM Alarm System S100 supports GSM Jammer interference!

The GSM Alarm System S100 with user friendly design idea, all operations and settings are visual and intuitive!

What you need is a SIMCard which supports Call ID function.

What advantages of the S100?

1.    Two-way Voice communication or wiretap are available;

2.    LCD displays the entire setup menu;

3.    Armed, Partial Armed(At House or Stay), Disarmed, SOS are available;

4.    Armed delay, alarm delay, siren work or not, more other functions are Programmable by user;

5.    Watchdog,24Hours Zone, SOS zone are available;

6.    Using ICON to display armed, Partial Armed, Disarmed, Power status, Siren status and GSM Signal status.

7.    Auto-detect and report, GSM Signal Jammer alarm, SMS Switch is available.

 

Functions & Features of the GSM Alarm System:

Ø  GSM Frequency: Dual-Band(900/1800MHz), Quad-Band is optional(850/900/1800/1900Mhz) ;

Ø  Supports armed, Partial armed(At House or Stay) or disarmed, SOS  by remote control or mainframe keyboard;

Ø  Supports armed, disarmed, inquiry mainframe status, switch on or off relay output by SMS Commands;

Ø  Automatically send SMS Alert and dial to the pre-set cell phone when any sensor had been triggered;

Ø  Equips with 16 Wireless Zones, zone attribute (Normal/At House or Stay mode) and Zone Name is editable;

Ø  3 X 24-Hour zones for smoke and gas leakage sensor,1XWatchdog zone for monitoring elder or child, 1XSOS zone for emergency help;

Ø  Supports 3 SMS Alert Numbers and 5 Calling alert numbers and 20 Alarm Records for owner review;

Ø  Supports Timer for automatically arm or disarm the system;

Ø  Supports armed delay to give enough time to you go out the home, the delay time is editable by user;

Ø  Equips with 1 Alarm-Link output relay, once the system triggered, the output will switch on for 4minutes;

Ø  Equips with 1 independent output relay, it can be switch on or off by SMS Commands. This is very useful for remote switch on light or off while you’re in another city in the night;

Ø  The Keypad can use as a dialer, the functions like the Cell phone;

Ø  The external power failure & recovery alert function is optional ;

Ø  Supports wiretap through the internal microphone;

Ø  Supports internal Speaker to special user for two-way voice communication;

Ø  It is Compatible with PT2262/2264 and PT2242 wireless IC;

Ø  Standby internal rechargeable battery which can last 12 hours;

Ø  Based on the GSM communication network and Operation Menu Display technology, apply to wide range situations.

Ø  More programmable functions and features are available.

 

Standard Package list of the GSM Alarm System

Mainframe X1

Remote contol X2

Wireless PIR Motion Sensor X1

Wireless Door magnetic Sensor X1

Wired Siren X1

GSM Antenna X1

AC/DC AdaptorX1

User Manual

Optional Accessories( Wireless):

Combined Light and Siren    PIR Motion Sensor   Glass Break Sensor

Magnetic Window Sensor    Magnetic Steel Scrolling Door Sensor

Infrared Photoelectric Beam Fence   Wireless Strobe Siren

Our Other Wireless Sensors

Working Principle Drawing:

The S100 works with wireless detectors only. It can switch on or off one appliance by SMS command. Please see below:

Specifications of Mainframe of the GSM Alarm System

Rated Voltage:  9~12VDC 1.5A

Standby current: 30-40mA

Siren Output Voltage: 12VDC

Working temperature:  -10+60

Storage temperature:  -20+60

Relative humidity:     10-90%, No condensation

Work frequency:       900/1800 MHz or 850/900/1800/1900MHz

Communication protocol:   GSM PHASE 2/2+ (include data service)

Wireless sensor receiving frequency:     433.92 MHz

Wireless sensor permission quantity:     16Pcs

Remote Control permission quantity:      5Pcs

Effective distance wireless o, f remote control: 100 m

Battery: Built-in lithium-ion batte, ry:  1000mAh@3.7V

        Standby time Approx.12hours (depending on the network condition)

Size: 180mmX125mmX30mm (LXWXH)

Net Weight: 0.32Kg

Reference Standards:

UL1023:2004: Safety Household Burglar-Alarm System Units

UL 985:2004: Household Fire Warning System Units.

UL1635: Digital Alarm Communicator System Units.

EN 55022:1998: Emission Standard for information Technology Equipment.

EN 50024:1998: Immunity Standard for Information Technology Equipment.

EN 50130-4:1996: Immunity Standard for Fire, Intruder and Social Alarm Systems.

EN 60950:2000: Safety of information technology equipment.

EN 50131-1: 2004: Intrusion Systems General Requirements-Security Grade 2, Environment Class II.

PD 6662:2004: Scheme for the application of European Standards for intruder alarm systems.

DD 243:2004: Installation and configuration of intruder alarm systems designed to generate confirmed alarm conditions-code of practice.

EN 300220: Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 Mw.

ETS 300683: Radio equipment and systems (RES) – Electromagnetic compatibility (EMC) standard for Short Range Devices (SRD) operating on frequencies between 9 kHz and 25 GHz.

EN 50136-2-1: Alarm systems. Alarm transmission systems and equipment. General requirements for alarm transmission equipment.

TBR 21:  European Telecommunications Standards Institute.

 

GB 12663-2001: 防盗报警控制器通用技术条件。

GB/T 15211-1994: 报警系统环境试验.

GB/T 15408-1994: 报警系统电源装置、测试方法和性能规范。

GB/T 16571-1996: 文物系统博物馆安全防范工程设计规范 

GB/T 16572-1996: 防盗报警中心控制台。

GB/T 16676-1996: 银行营业场所安全防范工程设计规范。

GB 16796-1997: 安全防范报警设备 安全要求和试验方法。

GB 50348-2004: 安全防范工程技术规范。

 

Reading:9413  Issused Time:2010-03-30 【Print】 【Add Favorite
Contact Us  |  Legal  |  Friendly Link  |  Sitemap
Copyright © 2001-2010 King Pigeon Hi-tech. Co., Ltd.    TEL:0086-755-2906 3895 Ext.801, 802,803,804,805